		File Name: 90P4153.txt

	IBM NetBAY Remote Console Manager Code Update
		VERSION: Application 2.0
			05/09/03

	Contents:
	---------

	1.0 Supported Products
	2.0 Software Release Notes
	3.0 Known Issues
	4.0 Update Procedures
	5.0 Web Sites and Support Phone Number
	6.0 Trademarks and Notices
	7.0 Disclaimer



	1.0 Supported Products

	    1.1 PRODUCTS THAT SUPPORT THIS CODE:

		Software version: 2.0
		Products that support this code:
		1735R16
		32P1651
 
		Firmware Version 2.0  
		Products that support this code:
		1735R16
		32P1651
		1735L04
		32P1635



	2.0 Software Release Notes

	    2.1 IBM RCM Software RELEASE NOTES (Version 2.0)
	
	    	This software and firmware is an update for the IBM ACT Product line
	    	and includes functionality for the USB Conversion Option (UCO).


	    2.2 The following are features/enhancements to RCM/LCM Firmware.

		1.	UCO - USB Conversion Option for connection to USB only 
			Servers. 
		2.	Diagnostics -The OSCAR commands screen  has been updated to
			provide diagnostics capability to the local user.
		3.	Remote User Preemption of Local User - The appliance will 
			allow a remote user that has Administrator or Appliance 
			Administrator access level privilege to preempt a local user 
			who is currently connected to a server.
		4.	PS/2 Reset - Currently, The Local user can cause a reset 
			sequence to be sent to the currently connected server by 
			selecting the "Reset PS/2" button on the OSCAR Commands 
			screen.  If the server is not running Windows, the reset
			sequence can result in the possible loss of keyboard and/or 
			mouse functionality.  A new PS/2 Reset Warning message 
			alerts the user to this possibility and gives him the option 
			to cancel the reset operation.
		5.	Scan Feature/Menu Select -The scan screen in OSCAR has been 
			updated to allow the local user to define a list of servers 
			to include while in scan mode and the amount of time to 
			display each server.
		6.	Sorting OSD List by Port - If the local user sorts an OSCAR
			list by Port the list will display either the Name or eID 
			for each list entry based on the user's default sort 
			preference (selected on the OSCAR Menu screen).  If the 
			default sort order is Names the port sorted lists will show 
			the entry's name by default, otherwise the port sorted lists 
			will show the entry's eID. The user can override this 
			default	behavior in any screen by first sorting the OSCAR 
			list by Name or eID, then by Port.  In this case, the port 
			sorted list will display the Name or eID based on the user's 
			previous selection.  This override mechanism is local to the 
			current screen, and is forgotten when the user leaves the 
			screen.
		7.	Toggle Name/eID - The Names screen in OSCAR has been 
			modified to include a "Toggle Name/eID" button.  This button 
			causes the first field in all the rows to toggle between the 
			COs Name and the COs eID.  The reason for adding this new 
			button is to make it easier to manage changing the names 
			when several COs on the same port have the same name.


	    2.3 The following are features/enhancements to the NetBAY Virtual 
		Console Software application. 

		1.	Video Viewer Scan Mode Feature - The NetBAY Virtual Console
			software client application has been updated to provide a 
			Video Viewer scan mode feature for viewing servers. The 
			primary purpose of the scan mode is to allow the user to 
			observe a small image of each server to determine if there 
			is anything wrong with the server that might need the 
			attention of the user.
		2. 	Server Name in Full Screen - The software client application 
			has been modified to display the server name when in full 
			screen mode.
		3.	Video Viewer Macro Updates - To provide functionality for 
			servers that need to distinguish between the left and right 
			Alt, Ctrl and Shift keys, primitives have been added to the 
			Video Viewer macro creation capability so that the left and 
			right Alt, Ctrl, and Shift keys may be specified.
		4. 	Connections Window - The server connection path screen has 
			been modified to also display the IP Address of the RCM and 
			the physical port number that the CO cable is attached to.
		5.	Security Lockout - The Security Lock-Out feature will 
			temporarily disable an account if the user enters an invalid 
			password five consecutive times.  If a user attempts to 
			login to a locked account, the software client application 
			will display an appropriate error message.  All accounts 
			(user, user admin, and appliance admin) are subject to this 
			lockout policy.
		6.	Remote User can Preempt Local User - The software client 
			application has been updated to provide the capability for 
			a user that has Administrator or Appliance Administrator 
			access rights to preempt a local user who is currently 
			connected to a server. 

	    2.4 IBM RCM Software RELEASE NOTES (From Version 1.2a)

	    	This firmware solved the following problems:

	    	1.	Fixed the following Foreign Language Keyboard issues:					
                	- When an operator entered certain keystrokes on a remote 
	          	client workstation through an international keyboard (e.g.:
			German), the character that should have appeared on the 
			remote target device did not appear correctly.  In addition, 
			keystrokes for primarily European keyboards, such as the 
			ALT-GR were not trasmitted properly.					
					
	    	2.	Novell Macro Primitives support					
                	- The following new macro primitives have been added to 
			support the creation of macros for Novell target devices.					
                    	* Alt-Left-PRESS					
                    	* Alt-Left-RELEASE					
                    	* Alt-Right-PRESS					
                    	* Alt-Right-RELEASE					
                    	* Ctrl-Left-PRESS					
                    	* Ctrl-Left-RELEASE					
                    	* Ctrl-Right-PRESS					
                    	* Ctrl-Right-RELEASE					
                    	* Shift-Left-PRESS					
                    	* Shift-Left-RELEASE					
                    	* Shift-Right-PRESS					
                    	* Shift-Right-RELEASE					

	
	

	3.0 Known Issues:

	    3.1 APPLIANCE:
		
	    	1.	Ballistic mouse occurs when it is hotplugged on a local 
			port on an RCM. Problem can be resolved by performing 
			a second hotplug or by conducting a PS/2 reset.
	    	2.	Help screens in LCM 2.0.6.3 refer to RCM instead of LCM.
	    	3.	Incorrect instructions in User Status disconnect screen 
			for LCM and RCM.  Under OSCAR -> Commands -> User Status, 
			the instructions should say that you must type Alt+A, 
			Alt+B or Alt+C, or click on A, B or C with the mouse,
			to disconnect.
	    	4.	The LAN is referenced in the LCM Diagnostic section, which
			is local only.  Disregard the LAN references in this 
			section.


	    3.2 CLIENT:

	    	1.	When using RedHat Linux 7.2 OS, NumLock "on" blocks all 
			alpha input from the keyboard for Video Viewer for French,
			Italian, and Spanish keyboards.  If this occurs, turn 
			Numlock "off" to return back to normal
	    	
	   	
	    3.3 Resolved Issues (from version 1.2a):

	    	1.	In the Database Export dialog, when you typed in a file 
			name, then changed the file type, the name became blank. 
			The typed in name should have remained in the file name 
			field after changing the file type.  The workaround for 
			this was to select the type of file first (*.tsv or *.csv), 
			then enter the file name.				



	4.0 UPDATE PROCEDURE:

	    4.1 Download 90P4153.ZIP 
		Unzip 90P4153.ZIP 
		You should now have 4 folders named LCM, RCM, Linux, and Win32. 
		
		The contents of the above mentioned folders are as follows: 
		
		LCM = Version 2.0 firmware for the LCM 
		
		RCM = Version 2.0 firmware for the RCM 
		
		Linux = Setup.bin - necessary to install Version 2.0 of the NetBAY 
		Virtual Console Software on Linux Systems. 
		
		Win32 = Setup.exe - necessary to install Version 2.0 of the NetBAY 
		Virtual Console Software on Windows Systems. 
		
		To upgrade LCM firmware, see your LCM User Guide. 
		To upgrade RCM Firmware, see your RCM User Guide. 
		To upgrade NetBAY Virtual Console Software, simply select the 
		appropriate file for your system(setup.exe for Windows or setup.bin 
		for Linux)to launch the software install wizard.



	5.0   WEB Sites and Support Phone Number
       	     
	    5.1  IBM Support Web Site:
                 http://www.pc.ibm.com/support

            5.2  IBM Marketing eserver Web Site:
                 http://www.ibm.com/eserver/xseries

            5.3  If you have any questions about this update, or problems
                 applying the update go to the following Help Center World
                 Telephone Numbers URL: 800-IBM-SERV (800-426-7378)
                 http://www.pc.ibm.com/qtechinfo/YAST-3P2QYL.html.
	     
            5.4  IntelliStation web site:
                 www.pc.ibm.com/intellistation   



       6.0   Trademarks and Notices
       
            6.1   The following terms are trademarks of the IBM Corporation
                  in the United States or other countries or both:
		  IBM, NetBAY

	    6.2   Windows is a trademark of Microsoft Corporation.
                  
	    6.3   Linux is a trademark of Linus Torvalds.

            6.4   Other company, product, and service names may be
                  trademarks or service marks of others.



	7.0   Disclaimer
       

            7.1   THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF
                  ANY KIND.   IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS
                  OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED
                  WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND
                  MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS
                  DOCUMENT.   BY FURNISHING THIS DOCUMENT, IBM GRANTS NO
                  LICENSES TO ANY PATENTS OR COPYRIGHTS.

            7.2   Note to Government Users
                  Include the following note after the disclaimer paragraph.

                  Note to U.S. Government Users -- Documentation related to
                  restricted rights -- Use, duplication or disclosure is
                  subject to restrictions set forth in GSA ADP Schedule
                  Contract with IBM Corporation.